Contact
Applications
The H05V-U and H07V-U cables are color-coded PVC sheathed, copper single-core stranded wires. Specially suitable for application in:
● internal wiring of appliances
● power and lighting circuits and general building wiring
● in closed installation ducts, or in embedded or semi-flush exposed conduits
For any more information or advice please contact the office on 0086-18832134509 (WhatsApp/WeChat)
Details
PVC Insulated Flexible Cable
The PVC sheathing cable is available as a Class 1 solid copper conductor (H05V-U) or Class 2 stranded copper conductor (H07V-U) . Both types are suitable for power and lighting circuits and general building wiring.
The PVC sheathing cable is intended for use in closed installation ducts, or in embedded or semi-flush exposed conduits. It is designed to be easily drawn into conduit and trunking, and it is ideal for the internal wiring of appliances in an enclosed and protected environment. It can also be used as an earthing cable (where the green/yellow insulation colour is applicable).
Construction
Description: H05V-U &H07V-U, PVC Insulated Copper Cable
Conductors: Class1 solid copper or Class2 of plain annealed stranded copper
Insulation: Polyvinyl chloride PVC
Colour of Sheath: Any Colour
Voltage Rating (Uo/U) H05V-U: 300/500V H07V-U:450/750V
Test Voltage H05V-U: 2kV for 5 minutes H07V-U: 2.5kV for 5 minutes
Physical Properties
Maximal operating conductor Temperature: up to 70℃(PVC insulation); up to 90℃(XLPE insulation)
Operating Temperature Range: -5℃(PVC or LSZH sheath); -20℃(PE sheath)
Short Circuit Temperature(5 seconds maximum duration): 140℃-160℃(PVC insulation);250℃(XLPE insulation)
Technical Data
300/500V H05V-U PVC Insulated cable | ||||
No. of cores and nominal cross section | Thickness of Insulation | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) |
(mm2) | (mm) | (mm) | (kg/km) | (Ω/km) |
1 X 0.5 | 0.6 | 2.1 | 9 | 36.0 |
1 X 0.75 | 0.6 | 2.2 | 11 | 24.5 |
1 X 1 | 0.6 | 2.4 | 14 | 18.1 |
450/750V H07V-U PVC Insulated cable | ||||
No. of cores and nominal cross section | Thickness of Insulation | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) |
1 X 1.5 | 0.7 | 2.8 | 20 | 12.1 |
1 X 2.5 | 0.8 | 3.5 | 31 | 7.41 |
1 X 4 | 0.8 | 4.1 | 45 | 4.61 |
1 X 6 | 0.8 | 4.5 | 65 | 3.08 |
1 X 10 | 1.0 | 6.0 | 109 | 1.83 |
1 X 16 | 1.0 | 7.0 | 163 | 1.2 |
1 X 25 | 1.2 | 8.7 | 256 | 0.727 |
1 X 35 | 1.2 | 9.8 | 345 | 0.524 |
1 X 50 | 1.4 | 11.5 | 471 | 0.387 |
1 X 70 | 1.4 | 13.3 | 667 | 0.268 |
1 X 95 | 1.6 | 15.5 | 919 | 0.193 |
1 X 120 | 1.6 | 16.2 | 1131 | 0.153 |
1 X 150 | 1.8 | 18.1 | 1401 | 0.124 |
1 X 185 | 2.0 | 20.2 | 1749 | 0.0991 |
1 X 240 | 2.2 | 23 | 2295 | 0.0754 |
1 X 300 | 2.4 | 25.6 | 2856 | 0.0601 |
1 X 400 | 2.6 | 29 | 3715 | 0.047 |