Contact
Applications
Multi Cores Flexible Cables are suited for purposes requiring special flexibility in conditions free of any mechanical stresses. Specially suitable for application in:
· Connection of Light Household Devices
· Small Power Tools Require Flexible Cable
· Instrument and Meter Electric Wire
· Cooking and heating appaaratus
· Furniture, partition walls, decorative covering, and in the hollow spaces of prefabricated building parts
For any more information or advice please contact the office on 0086-18832134509 (WhatsApp/WeChat)
Details
Flexible cable for dry areas, used for purposes requiring special flexibility in conditions free of any mechanical stresses. Permitted frequent bending and twisting.
Specially suitable for application in small devices with low mechanical loads and for connection of light household devices such as kitchen appliances, desk lamps, ceiling lamps, vacuum cleaners, office machines, radios etc., as long as the cable is adapted to essential Specification of the device.
These cables must not be used for cooking and heating devices. They are not suitable for outdoor use or for industrial (except for sewing - machines and similar) and agricultural machines.
Description: H05VV-F, PVC Insulated PVC Sheathed Copper flexible Cable
Conductors:Class 5 of plain annealed flexible stranded copper in accordance with IEC 60228.
Insulation:Polyvinyl chloride PVC
Filler: Non-hygroscopic Material if needed
Wrapping: PP Material if needed
Outer Sheath: Polyvinyl Chloride PVC
Colour of Sheath: Black
Voltage Rating (Uo/U) 300/500V Test Voltage 2kV for 5 minutes
Physical Properties
Maximal operating conductor Temperature: up to 70℃(PVC insulation); up to 90℃(XLPE insulation)
Operating Temperature Range: -5℃(PVC or LSZH sheath); -20℃(PE sheath)
Short Circuit Temperature(5 seconds maximum duration): 140℃-160℃(PVC insulation);250℃(XLPE insulation)
Technical Data
300/500V-Multi Cores PVC Insulated PVC Sheath flexible cable | ||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) | Current carrying capacity |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | (A) |
2 X 0.75 | 0.6 | 0.8 | 6.0 | 48 | 26.0 | 10 |
2 X 1 | 0.6 | 0.8 | 6.2 | 59 | 19.5 | 12 |
2 X 1.5 | 0.7 | 0.8 | 6.8 | 76 | 13.3 | 15 |
2 X 2.5 | 0.8 | 1.0 | 8.4 | 116 | 7.98 | 21 |
2 X 4 | 0.8 | 1.1 | 9.7 | 171 | 4.95 | 28 |
3 X 0.75 | 0.6 | 0.8 | 6.0 | 61 | 26.0 | 10 |
3 X 1 | 0.6 | 0.8 | 6.3 | 80 | 19.5 | 12 |
3 X 1.5 | 0.7 | 0.9 | 7.4 | 111 | 13.3 | 15 |
3 X 2.5 | 0.8 | 1.1 | 9.2 | 169 | 7.98 | 21 |
3 X 4 | 0.8 | 1.1 | 10.3 | 235 | 4.95 | 28 |
4 X 0.75 | 0.6 | 0.8 | 6.6 | 78 | 26.0 | 10 |
4 X 1 | 0.6 | 0.9 | 7.1 | 104 | 19.5 | 12 |
4 X 1.5 | 0.7 | 1.0 | 8.4 | 143 | 13.3 | 15 |
4 X 2.5 | 0.8 | 1.1 | 10.1 | 211 | 7.98 | 21 |
4 X 4 | 0.8 | 1.2 | 11.5 | 296 | 4.95 | 28 |
5 X 0.75 | 0.6 | 0.9 | 7.4 | 94 | 26.0 | 10 |
5 X 1 | 0.6 | 0.9 | 7.8 | 124 | 19.5 | 12 |
5 X 1.5 | 0.7 | 1.1 | 9.3 | 176 | 13.3 | 15 |
5 X 2.5 | 0.8 | 1.2 | 11.2 | 261 | 7.98 | 21 |
5 X 4 | 0.8 | 1.3 | 12.8 | 372 | 4.95 | 28 |