11kV 33kV Medium Voltage MV Aerial Bundled Conductor (ABC) XLPE Cables

Applications

Aerial Bundle Cables, often referred to as Aerial Bundled Conductors or simply ABC Cable, are cables for overhead line power, so called for combining multiple single core cables together. Its mainly applications are:

 For overhead service applications such as street lighting,outdoor lighting,and temporary service for construction 

 For medium voltage aerial power distribution;

 For transformer feeders, power plants, industrial and operation installations;

  For tree-lined urban zones or with little space

 For any more information or advice please contact the office on 0086-18832134509(WhatsApp/WeChat)

Share:

Details

Overview

MV Aerial Bundled Cables (ABC Cable)

Aerial Bundle Cables, often referred to as Aerial Bundled Conductors or simply ABC Cable, are cables for overhead line power. The cable as a new-type aerial cable is extensively used in rebuilding of urban and forest region electrified wire netting,for temporary power distribution to street lighting and secondary pole-to-pole service cables, for transmitting electric power overhead, and they are more commonly used in temporary power installations such as on construction sites. It improves the safety and reliance of electrified wire netting.

Construction

11kV  33kV Medium Voltage MV Aerial Bundled Conductor (ABC) XLPE Cables

Types of Cable Construction11kV  33kV Medium Voltage MV Aerial Bundled Conductor (ABC) XLPE Cables

Description:  Overhead Cable,Aerial Bundled Conductor (ABC)Cables  

Conductor:  Circular Compacted Class 2 Stranded Aluminum or Alloy Aluminum Conductor

Conductor Screen: Semi-conductive compound

Insulation:  Cross linked polyethylene XLPE Insulation

Insulation Screen: Semi-conductive compound

Metallic Screen: Copper tape screen(SCT) or Copper wire screen(SCW)

Outer Sheath: HDPE or PVC

Support Conductor: Stranded Galvanized steel wires

Assembly the three XLPE insulated and copper wire screened single core cables are bundled around the galvanized steel wires in a right hand lay.

Physical Properties

Maximal operating conductor Temperature: up to 70℃(PVC insulation); up to 90℃(XLPE insulation)

Operating Temperature Range: -5℃(PVC or LSZH sheath); -20℃(PE sheath)

Short Circuit Temperature(5 seconds maximum duration): 140℃-160℃(PVC insulation);250℃(XLPE insulation)

Technical Data

AS/NZS 3599 Part 1   6.35/11 kV Al/XLPE /HDPE Non-Screened Cables
Number of Cores x
Nominal Cross   Section
Phase ConductorMessenger Suspension UnitNominal
Sectional
Area
Breaking Load
Diameter of ConductorThickness of InsulationThickness of Insulation ScreenThickness of SheathStranding
No.*mm²mmmmmmmmNo./mmmm²KN
3x356.93.40.81.27/4.7552.41370
3x508.13.40.81.27/4.7554.61530
3x709.73.40.81.27/4.7557.81790
3x9511.43.40.81.27/4.7561.32100
3x12012.83.40.81.219/3.5067.32540
3x15014.23.40.81.219/3.5070.12840
3x18515.73.40.81.219/3.5073.13190
other cross-sections can be offered upon request.
AS/NZS 3599 Part 1   12.7/22 kV Al/XLPE /HDPE Non-Screened Cables
Number of Cores x
Nominal Cross   Section
Phase ConductorMessenger Suspension UnitNominal
Sectional
Area
Breaking Load
Diameter of ConductorThickness of InsulationThickness of Insulation ScreenThickness of SheathStranding
No.*mm²mmmmmmmmNo./mmmm²KN
3x356.95.50.81.27/4.7561.0 1780
3x508.15.50.81.27/4.7563.31970
3x709.75.50.81.27/4.7566.52260
3x9511.45.50.81.27/4.7569.92600
3x12012.85.50.81.219/3.5075.93070
3x15014.25.50.81.219/3.5078.73390
3x18515.75.50.81.219/3.5081.73760
other cross-sections can be offered upon request.


Contact Us Now