CU/XLPE/PVC Unarmored N2XY YJV XLPE insulated power cables

Applications

The 0.6/1 KV CU/XPLE/PVC cable plays a vital role in low-voltage power transmission and distribution, widely applied in building,industrial, and infrastructure settings to ensure the reliability and safety of power systems. These cables are used for electricity supply in low voltage installation system, They are suitable for: 

installation in indoors and outdoors 

in cable ducts

underground

in power and switching stations

local energy distributions

industrial plants

where there is no risk of mechanical damage.

 For any more information or advice please contact the office on 0086-18832134509(WhatsApp/WeChat)

Share:

Details

Overview

XLPE Insulated,PVC Sheathed Cable,0.6/1kV

The 0.6/1 KV CU/XPLE/PVC cable plays a vital role in low-voltage power transmission and distribution, widely applied in building,industrial, and infrastructure settings to ensure the reliability and safety of power systems. This Power Cable with stranded compacted copper conductor(CU), cross-linked polyethylene insulation (XPLE), and a polyvinyl chloride sheath (PVC). For fixed installation in interiors,outdoor installation,in soil,in water and concrete,if no posterior mechanical damage is to be expected.

Construction

CU/XLPE/PVC Unarmored N2XY YJV XLPE insulated power cables

Description: N2XY, XLPE Insulated Copper Power Cable  

Conductors: Class 1 or Class 2 of plain copper,or of Class 5 of plain copper in accordance with IEC 60228.

Insulation: Cross-linked polyethylene XLPE

Insulation Colour: Natural or as required

Filler: Non-hygroscopic Material

Outer Sheath: Extruded Polyvinyl Chloride PVC&Polyethylene PE&LSZH

Colour of Sheath: Black

Voltage Rating (Uo/U): 600/1000V   Test Voltage: 3.5kV for 5 minutes

Physical Properties

Maximal operating conductor Temperature: up to 70℃(PVC insulation); up to 90℃(XLPE insulation)

Operating Temperature Range: -5℃(PVC or LSZH sheath); -20℃(PE sheath)

Short Circuit Temperature(5 seconds maximum duration): 140℃-160℃(PVC insulation);250℃(XLPE insulation)

Technical Data

                                                                                            0.6/1kV-3+1 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
3X2.5+1X1.50.7/0.71.8 12.3 2007.41/12.12839
3X4+1X2.50.7/0.71.8 13.4 2604.61/7.413751
3X6+1X40.7/0.71.8 14.6 3503.08/4.614764
3X10+1X60.7/0.71.8 16.9 4801.83/3.086586
3X16+1X100.7/0.71.8 19.4 7601.15/1.8384110
3X25+1X160.9/0.71.8 22.8 10400.727/1.15110140
3X35+1X160.9/0.71.8 25.1 14200.524/1.15135170
3X50+1X251.0/0.91.8 28.2 18300.387/0.727170205
3X70+1X351.1/0.91.9 31.9 25000.268/0.524215250
3X95+1X501.1/1.02.135.7 34000.193/0.387265300
3X120+1X701.2/1.12.239.6 43000.153/0.268310345
3X150+1X701.4/1.12.343.6 52000.124/0.268350385
3X185+1X951.6/1.12.549.8 65000.0991/0.193405435
3X240+1X1201.7/1.22.755.3 85000.0754/0.153480500
3X300+1X1501.8/1.42.957.0 100000.0601/0.124555565
3X400+1X1852.0/1.73.170.0 133000.0470/0.0991640640
0.6/1kV-4+1 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
4X2.5+1X1.50.7/0.71.8 13.2 2207.41/12.12839
4X4+1X2.50.7/0.71.8 14.5 3204.61/7.413751
4X6+1X40.7/0.71.8 15.9 4203.08/4.614764
4X10+1X60.7/0.71.8 18.5 6501.83/3.086586
4X16+1X100.7/0.71.8 21.3 9501.15/1.8384110
4X25+1X160.9/0.71.8 25.7 14500.727/1.15110140
4X35+1X160.9/0.71.8 28.2 18500.524/1.15135170
4X50+1X251.0/0.91.9 28.9 25000.387/0.727170205
7X70+1X351.1/0.92.0 32.2 34500.268/0.524215250
4X95+1X501.1/1.02.236.9 47000.193/0.387265300
4X120+1X701.2/1.12.340.8 60000.153/0.268310345
4X150+1X701.4/1.12.544.7 71000.124/0.268350385
4X185+1X951.6/1.12.750.7 90000.0991/0.193405435
4X240+1X1201.7/1.22.956.4 104000.0754/0.153480500
4X300+1X1501.8/1.43.164.0 135000.0601/0.124555565
0.6/1kV-3+2 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
3X2.5+2X1.50.7/0.71.8 13.0 2007.41/12.12839
3X4+2X2.50.7/0.71.8 14.3 2604.61/7.413751
3X6+2X40.7/0.71.8 15.6 3503.08/4.614764
3X10+2X60.7/0.71.8 17.9 4801.83/3.086586
3X16+2X100.7/0.71.8 20.8 7601.15/1.8384110
3X25+2X160.9/0.71.8 25.2 10400.727/1.15110140
3X35+2X160.9/0.71.8 26.8 14200.524/1.15135170
3X50+2X251.0/0.91.9 28.7 18300.387/0.727170205
3X70+2X351.1/0.92.0 32.2 25000.268/0.524215250
3X95+2X501.1/1.02.236.7 34000.193/0.387265300
3X120+2X701.2/1.12.340.8 43000.153/0.268310345
3X150+2X701.4/1.12.444.5 52000.124/0.268350385
3X185+2X951.6/1.12.650.5 65000.0991/0.193405435
3X240+2X1201.7/1.22.856.1 85000.0754/0.153480500
3X300+2X1501.8/1.43.063.7 100000.0601/0.124555565






Contact Us Now