Contact
Applications
The 0.6/1 KV CU/XPLE/PVC N2XY (U-1000 R2V RVFV)cable plays a vital role in low-voltage power transmission and distribution, widely applied in building,industrial, and infrastructure settings to ensure the reliability and safety of power systems.They are used for electricity supply in low voltage installation system,suitable for:
● installation in indoors and outdoors
● in cable ducts
● underground
● in power and switching stations
● local energy distributions
● industrial plants
where there is no risk of mechanical damage.
For any more information or advice please contact the office on 0086-18832134509(WhatsApp/WeChat)
Details
XLPE Insulated,PVC Sheathed Cable,0.6/1kV
The 0.6/1 KV CU/XPLE/PVC cable(U-1000 R2V RVFV) plays a vital role in low-voltage power transmission and distribution, widely applied in building,industrial, and infrastructure settings to ensure the reliability and safety of power systems. This Power Cable with stranded compacted copper conductor is composed of copper conductor (CU), cross-linked polyethylene insulation (XPLE), and a polyvinyl chloride sheath (PVC). For fixed installation in interiors,outdoor installation,in soil,in water and concrete,if no posterior mechanical damage is to be expected.
Construction
Description: N2XY, XLPE Insulated Copper Power Cable
Conductors: Class 1 or Class 2 of plain copper,or of Class 5 of plain copper in accordance with IEC 60228.
Insulation: Cross-linked polyethylene XLPE
Insulation Colour: Natural or as required
Filler: Non-hygroscopic Material
Outer Sheath: Extruded Polyvinyl Chloride PVC&Polyethylene PE&LSZH
Colour of Sheath: Black
Voltage Rating (Uo/U): 600/1000V Test Voltage: 3.5kV for 5 minutes
Physical Properties
Maximal operating conductor Temperature: up to 70℃(PVC insulation); up to 90℃(XLPE insulation)
Operating Temperature Range: -5℃(PVC or LSZH sheath); -20℃(PE sheath)
Short Circuit Temperature(5 seconds maximum duration): 140℃-160℃(PVC insulation);250℃(XLPE insulation)
Technical Data
0.6/1kV-1 core copper conductor XLPE insulated PVC sheathed power cable | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of Sheath | Approx. overall Diameter | Approx. weight | Max. DC resistance of conductor(20℃) | Current carrying capacity | |
(mm2) | (mm) | (mm) | (mm) | (kg/km) | (Ω/km) | In Air(A) | In Ground(A) |
1X1.5 | 0.7 | 1.4 | 5.5 | 48 | 12.1 | 23 | 32 |
1X2.5 | 0.7 | 1.4 | 5.9 | 59 | 7.41 | 31 | 42 |
1X4 | 0.7 | 1.4 | 6.4 | 75 | 4.61 | 41 | 55 |
1X6 | 0.7 | 1.4 | 6.9 | 95 | 3.08 | 52 | 69 |
1X10 | 0.7 | 1.4 | 8.0 | 140 | 1.83 | 71 | 92 |
1X16 | 0.7 | 1.4 | 9.0 | 200 | 1.15 | 92 | 115 |
1X25 | 0.9 | 1.4 | 10.6 | 310 | 0.727 | 120 | 150 |
1X35 | 0.9 | 1.4 | 11.6 | 410 | 0.524 | 150 | 180 |
1X50 | 1.0 | 1.4 | 13.1 | 510 | 0.387 | 180 | 215 |
1X70 | 1.1 | 1.4 | 15.0 | 710 | 0.268 | 230 | 265 |
1X95 | 1.1 | 1.5 | 16.8 | 990 | 0.193 | 285 | 320 |
1X120 | 1.2 | 1.5 | 18.4 | 1230 | 0.153 | 335 | 360 |
1X150 | 1.4 | 1.6 | 20.5 | 1450 | 0.124 | 385 | 410 |
1X185 | 1.6 | 1.6 | 22.6 | 1800 | 0.0991 | 450 | 460 |
1X240 | 1.7 | 1.7 | 25.2 | 2300 | 0.0754 | 535 | 535 |
1x300 | 1.8 | 1.8 | 27.8 | 2960 | 0.0601 | 620 | 605 |
1x400 | 2.0 | 1.9 | 31.4 | 3800 | 0.0470 | 720 | 685 |
1x500 | 2.2 | 2.0 | 34.9 | 4800 | 0.0366 | 835 | 775 |
1X630 | 2.4 | 2.2 | 39.1 | 6100 | 0.0283 | 960 | 865 |