SWA Cable N2XRY Copper Conductor SWA 0.6/1kV Cable,CU/XLPE/SWA/PVC

Applications

N2XRH and N2XRY are copper power cables with a voltage rating of 600/1000V designed to withstand harsh operating conditions and mechanical stresses. They are suitable for :

            Power and auxiliary fixed wiring cables

            Power networks

            Underground

            Outdoor and indoor devices

For any more information or advice please contact the office on 0086-18832134509 (WhatsApp/WeChat)

Share:

Details

Overview

CU/XLPE/SWA/PVC Cable  

N2XRY (CU/XLPE/SWA/PVC)Armoured Power Cables are the toughest and most durable armoured cable for power distribution and transmission. Made with a layer of steel wire armoured (SWA), polyethylene (XLPE) thermosetting insulation, and hard-wearing PVC, these armoured cables can withstand twisting, crushing, impacts, temperature extremes, moisture, chemical hazards, and more.  N2XRY is a PVC insulated and sheathed cable. The N2XRH cable uses Low Smoke Zero Halogen compounds (also known as HFFR - halogen free flame retardant),delivering a voltage rating of 0.6/1kV (600V/1000V) and a maximum temperature rating of 90℃, are form part of our range of steel wire armoured low voltage power cables for power transmission & distribution. They are used frequently in building and construction across all industries.

The addition of SWA armouring allows for these cables to be direct buried in the ground without additional protection, protecting them from mechanical stresses and the risk of damage from external forces.  LSZH cable provides additional protection in the event of a fire, emitting none of the harmful halogen gases such as chlorine gas and emits reduced levels of the dense black smoke compare to PVC sheathed cables. As a result, the N2XRH cable is widely used in public buildings, tall constructions, as well as in refineries, automation plants and data centres.

Construction

SWA Cable N2XRY  Copper Conductor SWA 0.6/1kV Cable,CU/XLPE/SWA/PVC

Description: N2XRY, XLPE Insulated Copper Power Cable   

Conductors: Class 1 or Class 2 of plain copper,or of Class 5 of plain copper in accordance with IEC 60228.

Insulation: Cross-linked polyethylene XLPE

Insulation Colour: Natural or as required

Filler: Non-hygroscopic Material

Inner Sheath: Polyvinyl Chloride PVC

Reinforcement: Steel Wire

Outer Sheath: Extruded Polyvinyl Chloride PVC&Polyethylene PE&LSZH

Colour of Sheath:  Black

Voltage Rating (Uo/U): 600/1000V       Test Voltage: 3.5kV for 5 minutes

Physical Properties

Maximal operating conductor Temperature: up to 70℃(PVC insulation); up to 90℃(XLPE insulation)

Operating Temperature Range: -5℃(PVC or LSZH sheath); -20℃(PE sheath)

Short Circuit Temperature(5 seconds maximum duration): 140℃-160℃(PVC insulation);250℃(XLPE insulation)

Technical Data

0.6/1kV-2 core copper conductor XLPE insulated steel wire armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessSteel Wire diameterSheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity 
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
2X2.50.70.81.814.83647.4123 32 
2X40.70.81.815.74254.6130 41 
2X60.71.251.817.66463.0839 53 
2X100.71.251.820.18021.8353 70 
2X160.71.251.822.310081.1568 91 
2X250.91.61.826.314700.72791 116 
2X350.91.61.827.617120.524112 140 
2X5011.61.930.821230.387137 168 
2X701.12235.429740.268172 203 
2X951.122.139.537370.193214 249 
2X1201.222.342.944530.153249 284 
2X1501.42.52.44857440.124284 315 
2X1851.62.52.652.768110.0991326 357 









0.6/1kV-3 core copper conductor XLPE insulated steel wire armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessSteel Wire diameterSheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity 
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
3X2.50.70.81.815.34057.4120 27 
3X40.70.81.816.24814.6126 36 
3X60.71.251.818.36963.0833 45 
3X100.71.251.820.99301.8346 60 
3X160.71.251.823.311911.1559 77 
3X250.91.61.827.617450.72777 98 
3X350.91.61.82921000.52495 119 
3X5011.61.932.526280.387119 144 
3X701.122.137.937280.268151 175 
3X951.122.241.846920.193186 210 
3X1201.222.345.556450.153217 242 
3X1501.42.52.551.373500.124245 270 
3X1851.62.52.755.986980.0991284 305 
3X2401.72.52.962.1108370.0754336 350 
3X3001.82.5367.4129900.0601389 396 









0.6/1kV-4 core copper conductor XLPE insulated steel wire armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessSteel Wire diameterSheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity 
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
4X2.50.70.81.816.14727.4120 27 
4X40.71.251.818.16774.6126 36 
4X60.71.251.819.38043.0833 45 
4X100.71.251.822.310881.8346 60 
4X160.71.61.825.715711.1559 77 
4X250.91.61.829.720850.72777 98 
4X350.91.61.931.425430.52495 119
4X5011.6235.332140.387119 144 
4X701.122.241.245710.268151 175 
4X951.122.345.657820.193186 210 
4X1201.22.52.551.275570.153217 242 
4X1501.42.52.756.190800.124245 270 
4X1851.62.52.861.3108220.0991284 305 
4X2401.72.53.168.1135660.0754336 350 
4X3001.82.53.274.1163560.0601389 396 









0.6/1kV-5 core copper conductor XLPE insulated steel wire armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessSteel Wire diameterSheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity 
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
5X2.50.71.251.817.96457.4120 27 
5X40.71.251.819.17704.6126 36 
5X60.71.251.820.59253.0833 45 
5X100.71.61.824.614171.8346 60 
5X160.71.61.827.618121.1559 77 
5X250.91.61.932.224600.72777 98 
5X350.91.6234.130190.52495 119 
5X50122.239.741660.387119 144 
5X701.122.344.954430.268151 175 
5X951.12.52.551.374850.193186 210 
5X1201.22.52.755.990260.153217 242 
5X1501.42.52.861.4109120.124245 270 
5X1851.62.5367.6131190.0991284 305 
5X2401.72.53.374.8164270.0754336 350 
5X3001.83.153.583.2209150.0601389 396 



Contact Us Now