Contact
Applications
CU/XLPE/SWA/PVC Armoured Power Cables are the perfect choice when you need the toughest and most durable armoured cable for power distribution and transmission.They are suitable for use in:
● Intdoors and in cable ducts
● Outdoors,underground
● Switch-boards and power stations
● Transformer stations
● Industrial Plants
Due to the good laying and mechanical characteristic, this cable is suitable when mechanical protection is required or in applications where mechanical damages are expected to occur.
For any more information or advice, please contact the office on 0086-18832134509(WhatsApp/WeChat)
Details
CU/XLPE/SWA/PVC Cable
CU/XLPE/SWA/PVC Armoured Power Cables are the perfect choice when you need the toughest and most durable armoured cable for power distribution and transmission. Made with a layer of steel wire armoured (SWA), polyethylene (XLPE) thermosetting insulation, and hard-wearing PVC, these armoured cables can withstand twisting, crushing, impacts, temperature extremes, moisture, chemical hazards, and more. They're suitable for use in a range of environments, from industrial and manufacturing facilities to construction
Construction
Descriptions:N2XSRY Single Core Steel wire armoured MV Power Cable
Conductor:Copper, Class2,Circular compacted conductors
Conductor Screen: Non-metallic,semi-conducting compound
Insulation: Cross-linked polyethylene XLPE
Insulation Screen: Non-metallic,semi-conducting compound
Metallic Screen: Copper Tape
Inner Sheathing:Non-metallic,semi-conducting compound
Armouring: Non-magnetic Steel Wire Armour
Outer Sheath: Polyvinyl Chloride PVC&Polyethylene PE&LSZH
Physical Properties
Operating Temperature: up to 70℃(PVC insulation); up to 90℃(XLPE insulation)
Temperature Range: -5℃(PVC or LSZH sheath); -20℃(PE sheath)
Short Circuit Temperature(5 seconds maximum duration): 140℃-160℃(PVC insulation);250℃(XLPE insulation)
Nominal Voltages:U0/U 1.8/3kV , 6/10 kV, 12/20 kV, 18/30 kV
Technical Data
Single Core Cable(N2XSRY)-6/10KV | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of sheath | Approx. Overall Diameter | Approx. Weight | Max. DC Resistance of conductor(20℃) | Current Carrying Capacity | |
mm2 | mm | mm | mm | kg/km | Ω/km | in air(A) | in ground(A) |
1x35 | 3.4 | 1.8 | 28 | 1150 | 0.524 | 185 | 158 |
1x50 | 3.4 | 1.8 | 29 | 1310 | 0.387 | 220 | 185 |
1x70 | 3.4 | 1.9 | 31 | 1580 | 0.268 | 271 | 234 |
1x95 | 3.4 | 1.9 | 32 | 1900 | 0.193 | 326 | 266 |
1x120 | 3.4 | 2.0 | 34 | 2190 | 0.153 | 370 | 297 |
1x150 | 3.4 | 2.1 | 36 | 2570 | 0.124 | 411 | 324 |
1x185 | 3.4 | 2.1 | 38 | 2980 | 0.0991 | 460 | 357 |
1x240 | 3.4 | 2.2 | 40 | 3630 | 0.0754 | 528 | 400 |
1x300 | 3.4 | 2.2 | 42 | 4300 | 0.0601 | 587 | 435 |
1x400 | 3.4 | 2.4 | 46 | 5280 | 0.0470 | 637 | 455 |
1x500 | 3.4 | 2.5 | 51 | 6550 | 0.0366 | 700 | 488 |
1x630 | 3.4 | 2.6 | 55 | 8120 | 0.0283 | 764 | 518 |
Single Core Cable(N2XSRY)-8.7/15KV | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of sheath | Approx. Overall Diameter | Approx. Weight | Max. DC Resistance of conductor(20℃) | Current Carrying Capacity | |
mm2 | mm | mm | mm | kg/km | Ω/km | in air(A) | in ground(A) |
1x35 | 4.5 | 1.9 | 30 | 1290 | 0.524 | 185 | 158 |
1x50 | 4.5 | 1.9 | 31 | 1450 | 0.387 | 220 | 185 |
1x70 | 4.5 | 2.0 | 33 | 1730 | 0.268 | 271 | 234 |
1x95 | 4.5 | 2.0 | 35 | 2090 | 0.193 | 326 | 266 |
1x120 | 4.5 | 2.1 | 37 | 2400 | 0.153 | 370 | 297 |
1x150 | 4.5 | 2.1 | 38 | 2720 | 0.124 | 411 | 324 |
1x185 | 4.5 | 2.2 | 40 | 3150 | 0.0991 | 460 | 357 |
1x240 | 4.5 | 2.3 | 43 | 3820 | 0.0754 | 528 | 400 |
1x300 | 4.5 | 2.3 | 45 | 4490 | 0.0601 | 587 | 435 |
1x400 | 4.5 | 2.5 | 50 | 5650 | 0.0470 | 637 | 455 |
1x500 | 4.5 | 2.6 | 53 | 6770 | 0.0366 | 700 | 488 |
1x630 | 4.5 | 2.7 | 57 | 8360 | 0.0283 | 764 | 518 |
Single Core Cable(N2XSRY)-12/20KV | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of sheath | Approx. Overall Diameter | Approx. Weight | Max. DC Resistance of conductor(20℃) | Current Carrying Capacity | |
mm2 | mm | mm | mm | kg/km | Ω/km | in air(A) | in ground(A) |
1x35 | 5.5 | 1.9 | 32 | 1410 | 0.524 | 185 | 158 |
1x50 | 5.5 | 2.0 | 33 | 1590 | 0.387 | 220 | 185 |
1x70 | 5.5 | 2.0 | 35 | 1900 | 0.268 | 271 | 234 |
1x95 | 5.5 | 2.1 | 37 | 2250 | 0.193 | 326 | 266 |
1x120 | 5.5 | 2.1 | 39 | 2550 | 0.153 | 370 | 297 |
1x150 | 5.5 | 2.2 | 40 | 2900 | 0.124 | 411 | 324 |
1x185 | 5.5 | 2.2 | 42 | 3300 | 0.0991 | 460 | 357 |
1x240 | 5.5 | 2.3 | 45 | 3980 | 0.0754 | 528 | 400 |
1x300 | 5.5 | 2.4 | 48 | 4850 | 0.0601 | 587 | 435 |
1x400 | 5.5 | 2.5 | 52 | 5850 | 0.0470 | 637 | 455 |
1x500 | 5.5 | 2.6 | 55 | 7010 | 0.0366 | 700 | 488 |
1x630 | 5.5 | 2.8 | 60 | 8600 | 0.0283 | 764 | 518 |
Single Core Cable(N2XSRY)-18/30KV,19/33KV | |||||||
No. of cores and nominal cross section | Thickness of Insulation | Thickness of sheath | Approx. Overall Diameter | Approx. Weight | Max. DC Resistance of conductor(20℃) | Current Carrying Capacity | |
mm2 | mm | mm | mm | kg/km | Ω/km | in air(A) | in ground(A) |
1x50 | 8.0 | 2.2 | 39 | 2020 | 0.387 | 220 | 185 |
1x70 | 8.0 | 2.2 | 41 | 2310 | 0.268 | 271 | 234 |
1x95 | 8.0 | 2.3 | 43 | 2670 | 0.193 | 326 | 266 |
1x120 | 8.0 | 2.3 | 44 | 2980 | 0.153 | 370 | 297 |
1x150 | 8.0 | 2.4 | 47.0 | 3500 | 0.124 | 411 | 324 |
1x185 | 8.0 | 2.5 | 49 | 3960 | 0.0991 | 460 | 357 |
1x240 | 8.0 | 2.5 | 51 | 4650 | 0.0754 | 528 | 400 |
1x300 | 8.0 | 2.6 | 54 | 5400 | 0.0601 | 587 | 435 |
1x400 | 8.0 | 2.7 | 57 | 6440 | 0.0470 | 637 | 455 |
1x500 | 8.0 | 2.8 | 61 | 7630 | 0.0366 | 700 | 488 |
1x630 | 8.0 | 2.9 | 65 | 9250 | 0.0283 | 764 | 518 |